NuMI/MINOS DocDB


MINOS Document 942-v1

Modification of Droege HV Supplies for Ethernet Control of the Beam Monitoring Ion Chambers

Document #:
MINOS-doc-942-v1
Document type:
Numi-Note
Submitted by:
John Urish
Updated by:
John Urish
Document Created:
17 Jul 2003, 12:00
Contents Revised:
17 Jul 2003, 12:00
Metadata Revised:
17 Jul 2003, 12:00
Actually Revised:
08 Sep 2006, 21:17
Viewable by:
  • Public document
Modifiable by:
  • Same as Viewable by

Quick Links:
Latest Version

Abstract:
The Droege wire chamber power supplies that are
stocked at Fermilab by PREP have been modified to
provide remote setting and read-back by ethernet.
The voltage range has also been reduced to match
that needed by MINOS muon and hadron beam monitors.
Modifications and performance are described.
This is a Postscript document
Posted by Albert Erwin
Files in Document:
Other Files:
Keywords:
ELEC
Notes and Changes:
A. R. Erwin, D. Glover, H. Ping
Publication Information:
Droege HV Supplies are modified to provide ethernet
setting and readback of voltages. Stable voltage settings
are achieved between 0.5 and 1000 volts.